Home 
Company Introduction
About The Company
Sg. Long Ind. Profile
Our Mission
Board of Directors
Corporate Structure
Organisation Structure
Management Team
Core Business & Activities
Products & Services
Customer Satisfaction
Corporate Activities
Corporate Citizenship
 
  Intro & Applications
  Advantage of Usage
  Manufacturing Process
  Quality & Characteristics
  Certificates
  Successful Projects
 
 
 
 

 

Sungai Long Bricks Sdn Bhd

Advantage of Usage

FIRE RESISTANCE
2 HOURS UNBAKED CLAY BRICK
TESTED & APPROVED BY HEADQUATERS OF FIRE & RESCUE DEPARTMENT MALAYSIA;
CERTIFIED & GRANTED BY SIRIM QAS


The graph above shows the actual temperature/time curve 
of the furnace heating conditions in relation to the 
standard temperature/time curve.

TEST REPORT

Applicant: SUNGAI LONG BRICKS SDN. BHD.

Summary: A specimen of a non-load bearing bricks wall partition system, has been subjected to a test in accordance with BS 476:Part 22:1987, Clause 5 to determine it's fire resistance performance.

The non-load bearing brick wall partition consisted of unbaked clay bricks, each of size 216mm(L) x 102mm (W) x 64mm (T), The bricks were bonded together by cement and sand mortar of 1:3 ratio. Both sides of the bricks wall partition were plastered to an average thickness of 10.0mm.

The bricks were claimed to be made from a composition of clay/sand, cement and quarry dust (mix proportion in percentage by weight of 90 : 7 : 3 ) and density was found to be 1910km/m3.

The bricks in 2 pallets (1299 pieces) were sampled by En. Azalan Adnan of Unit Persijilan Barang, SIRIM QAS Sdn. Bhd. And request for test was made through Form PPDI - ref. PS032801.

The specimen satisfied the performance requirements specified in Clause 5 of BS 476:Part 22, for non-load bearing wall partition, for the following periods:

Integrity: 125 minutes
Insulation:
125 minutes

The test was discontinued after a period of 125 minutes.

Date of Test: 04.05.1998

 


 

 
Copyright SUNGAI LONG INDUSTRIES SDN. BHD. All rights reserved.